APC UTS6H Specifiche

Navigare online o scaricare Specifiche per Switch di rete APC UTS6H. APC UTS6H Specifications [de] [en] [fr] [it] Manuale Utente

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
Vedere la pagina 0
®
Hydronic
freewatt Plus
System,
Model
HDJ
INSTALLATION,
OPERATION &
MAINTENANCE
MANUAL
Information and speci cations in the manual were in effect at time
of printing of this manual. ECR International reserves the right to
discontinue, change speci cations or system design at any time
without notice and without incurring any obligation, whatsoever.
P/N # 240008214, Rev. C [01/2011]
Check our website frequently for updates:
www.freewatt.com
www.ecrinternational.com
Vedere la pagina 0
1 2 3 4 5 6 ... 67 68

Sommario

Pagina 1 - Hydronic

®Hydronic freewatt Plus System,Model HDJINSTALLATION, OPERATION & MAINTENANCE MANUALInformation and specifi cations in the manu

Pagina 2

102- INTRODUCTIONSystem Clearances to CombustiblesDimensions Boiler Honda MCHPTop 1" ( 8" for service) 14"Sides 1" (24" for s

Pagina 3

11Figure 2-8 MCHP Electrical Connection Details2- INTRODUCTIONFigure 2-9 MCHP Front Interface Details

Pagina 4

12Section provides brief description of components, controls, and accessories of hydronic freewatt PLUS System. 3.1 BoilerRefer to separate freewatt

Pagina 5

133.8 Websitefreewatt control module web site address is assigned to system at time of installation allowing homeowner and service provider to monito

Pagina 6

144 -APC UNIVERSAL TRANSFER SWITCH CONFIGURATIONNOTICEAPC universal transfer switch is provided for use with freewatt Plus system and is not intended

Pagina 7

154 - APC UNIVERSAL TRANSFER SWITCH CONFIGURATIONTable 4-1 Typical UTS6H Circuit Setup without UPSTypical UTS Circuit Setup without UPSPARAMETERCIRCU

Pagina 8

164 - APC UNIVERSAL TRANSFER SWITCH CONFIGURATIONTable 4-3 Typical UTS6H Circuit Setup with UPSTypical UTS Circuit Setup with UPSPARAMETERCIRCUITICI

Pagina 9

175.1 freewatt Hydronic Zone Thermostat Requirements:Select heat or heat/cool thermostat with following properties, except Zone-2. Zone 2 must use HA

Pagina 10 - 2- INTRODUCTION

186.1 freewatt Transfer Switch Model FTS-1.8freewatt• Transfer Switch is specifi cally designed for use with freewatt PLUS micro-combined heat and po

Pagina 11

197.1 CodesSee boiler manual for information pertaining to installation in State of Massachusetts.System incorporates gas-fi red, direct vent, condens

Pagina 12

21 - Safety Information... 32 - Introduction ... 43 - Components, C

Pagina 13

207.3 Considerations for System LocationBefore selecting location for system, following should be considered. Each system component considered for in

Pagina 14 - WARNING

217.6 Condensate Drain RequirementsInstall condensate drain lines with pitch down to fl oor • at minimum of ¼” per foot.External condensate pump (not

Pagina 15 - Delayable - Yes:

228.1 Place system to provide direct connections to: combustion air/vent piping system, • natural gas piping, • return and supply duct-work, • conden

Pagina 16

23Figure 8-2 Hydronic Freewatt PLUS System Distribution Piping Schematic with Zone Valves and Priority DHW Pump8.3 freewatt PLUS System Piping Pla

Pagina 17

248.4 Design TipsInstall bottom of Hydronic HI Module at height of • 32” to 42” above fl oor elevation where HONDA MCHP installed.Maximum 10ft. length

Pagina 18

25using tubing clamp.Long Life Coolant • In Tubing Installation: [Pump to MCHP; Figure 8-6]Cut section of Onix Tubing to extend from MCHP • unit’s lo

Pagina 19 - 7.1 Codes

268.8 HHI Module to Distribution ManifoldFollow industry standards when installing distribution • manifold.Install MCHP hydronic pump below manifold

Pagina 20

27freewatt PLUS • boiler and MCHP unit will produce condensate at rates up to 2 ½ US quarts per hour. Make provisions to drain condensate away from

Pagina 21

28All Onix and brass fi tting surfaces must be clean and • dry before making connection.Avoid making connections or splices in inaccessible • locations

Pagina 22 - 8 - PLACING THE SYSTEM

299.1 EGLS Introduction Exhaust Gas Leak Sensor System in addition to • separate, independently installed and operating UL approved Carbon Monoxide De

Pagina 23

31 - SAFETY INFORMATION WARNINGDo not install this system in mobile home! Boiler is not approved for installation in mobile home. Doing so could cau

Pagina 24

30NOTICEExhaust Gas Sensor’s cable connections must be installed properly or Hydronic freewatt PLUS System will not initialize and not operate (ERROR

Pagina 25

3110.1 General ConsiderationsPerform tasks outlined in Section 5 of • freewatt PLUS boiler Installation, Operation and Maintenance Manual, section “

Pagina 26 - 8- PLACING THE SYSTEM

32NOTICEInstall boiler per Direct Venting requirements. Install MCHP per Non-Direct Venting Requirements. Distinction is noted to ensure proper locat

Pagina 27

3311.1 Check Gas SupplyGas pipe to boiler must be correct size for length of run • and for total BTU per hour input of all gas utilization equipment c

Pagina 28

34 WARNINGElectric shock hazard. For your safety, turn off elec-trical power supply at service panel before making any electrical connections. Failure

Pagina 29

35Route 120 VAC power wiring from service switch to ECR • AR822-II and attach to 120 VAC power terminals.Route 120 VAC power wiring from junction / sw

Pagina 30 - 9 - EXHAUST GAS LEAK SENSOR

36External controls with their own 24VAC transformer may • be used on zones 3-6. Steering relays can be used through freewatt control module jumpers J

Pagina 31

3712.10 Honda MCHP Unit - Line Voltage ConnectionsRefer to Honda MCHP Installation Manual – Electrical • Connections Section before performing instal

Pagina 32 - MCHP Vent

38should not less than about 25% of total for building).Connect thermostat cable to thermostat. Use Honeywell • Genesis Cable, Model Number 22 AWG 10/

Pagina 33 - 11 - GAS SUPPLY PIPING

3912 - ELECTRICAL WIRING & CONNECTIONS12.15 MCHP Battery InstallationPlease see the Honda MCHP manual for installation of the MCHP battery.Honda M

Pagina 34

42- INTRODUCTION2.2 Application NotesMaximum design water temperature of 160°F. Heat • emitters sized for heat output using maximum design water temp

Pagina 35

4013 -COMMISSIONING AND STARTUP13.1 For System commissioning and startup procedures, refer to literature packet document “Hydronic freewatt PLUS Syste

Pagina 36

41Review maintenance and cleaning procedures as outlined in Installation, Operation and Maintenance Manuals of boiler and Honda MCHP before proceeding

Pagina 37

4214.2 Draining ProcedureIt may be necessary to drain system during maintenance operations. Follow procedure below:NOTICEUse caution while servicing a

Pagina 38 - 12.14 Internet Connection

4315 - DETAILED SEQUENCE OF OPERATION

Pagina 39

4415 - DETAILED SEQUENCE OF OPERATION

Pagina 40 - 13 -COMMISSIONING AND STARTUP

4515.1 MCHP Operation: freewatt PLUS• System is designed to preferentially provide heat to home and indirect water heater by operating MCHP unit.

Pagina 41

4615.3 Achieving Best freewatt PLUS System PerformanceHomeowner dollar, carbon dioxide emissions, and energy saving with freewatt PLUS is maximized b

Pagina 42 - 14 - MAINTENANCE AND CLEANING

4716.1 Troubleshooting ToolsVoltmeter with settings to check: 240 VAC, 120 VAC, • 24 VAC and 12 VDC;Continuity Tester;• Contact Thermometer; (Non-Co

Pagina 43

4816 - TROUBLESHOOTING WARNINGElectrical shock hazard may cause serious injury or death. Avoid touching live electrical contacts. Service shall be per

Pagina 44

4916 - TROUBLESHOOTING16.4 General TroubleshootingIf And Check or repairNo Control module or HI Module operation120 VAC electrical connec-tionsBlown

Pagina 45 - Demands:

5 WARNINGBurn and scald hazard. Failure to install mixing valve will result in hot water scalding hazard. Install mixing valve per manufacturer

Pagina 46 - Performance

5016 - TROUBLESHOOTINGTable 16-1 Alarm Codes for Service Required LED on freewatt Control ModuleERROR CODEINDICATES CHECK OR REPAIR1THERMOSTAT COMMUNI

Pagina 47

51Table 16-2Alarms Codes for Combined Heat and Power LED on freewatt Control ModuleCombined Heat Power LED StatusConditionRapid Flash (~5 per second)

Pagina 48

52Table 16-4 freewatt PLUS System FusesLocation QTY Amp Voltage Spares Shape SizeControl Module (Control board, GDB Fuse) 1 2 250 0 Cylinder 5mm X 20m

Pagina 49 - 16 - TROUBLESHOOTING

5317-1 Piping Schematic SymbolsCIRCULATOR(With Isolation Flanges)PRESSUREREDUCER VALVEFLOW CHECK VALVEBALL VALVEBACKFLOW PREVENTERAIR SEPARATORZONE V

Pagina 50

5417-2 Primary/Secondary Piping With Zone Valves and Domestic Hot Water Priority Circulator17 - PIPING AND WIRING SCHEMATICS

Pagina 51

5517-3 Primary/Secondary Piping With Circulators and Domestic Hot Water Priority Circulator17 - PIPING AND WIRING SCHEMATICS

Pagina 52

5617-4 Primary/Secondary Piping With Hydro-Air Handler and Domestic Hot Water Priority Circulator17 - PIPING AND WIRING SCHEMATICS

Pagina 53

5717-5 HDJ - 240 VAC Wiring Only17 - PIPING AND WIRING SCHEMATICS

Pagina 54

5817-6 HDJ - 120 VAC Wiring Only17 - PIPING AND WIRING SCHEMATICS

Pagina 55

5917-7 HDJ - 120 VAC Wiring - Control Module & Zone Pumps17 - PIPING AND WIRING SCHEMATICS

Pagina 56

62- INTRODUCTION2.3 Save These InstructionsRead this manual carefully and keep for future reference by service technician. Manual is considered perm

Pagina 57

6017-8 HDJ - 120 VAC Wiring - Control Module & Zone Valves17 - PIPING AND WIRING SCHEMATICS

Pagina 58

6117-9 HDJ - 120 VAC Wiring - Control Module & Hydro Air17 - PIPING AND WIRING SCHEMATICS

Pagina 59

6217-10 HDJ - Low Voltage Wiring Only17 - PIPING AND WIRING SCHEMATICS

Pagina 60

6317-11 HDJ Low Voltage Only Wiring - Control Module and Zone Pumps17 - PIPING AND WIRING SCHEMATICS

Pagina 61

6417-12 HDJ Low Voltage Only Wiring - Control Module & Zone Valves17 - PIPING AND WIRING SCHEMATICS

Pagina 62

6517-13 HDJ Low Voltage Only Wiring - Control Module & Zone Valves with Expansion Zones17 - PIPING AND WIRING SCHEMATICS

Pagina 63

6617 - PIPING AND WIRING SCHEMATICS17-13 HDJ Low Voltage Only Wiring - Control Module & Hydro Air

Pagina 64

6717 - PIPING AND WIRING SCHEMATICS17-14 MCHP Low Voltage Wiring

Pagina 65

An ISO 9001-2008 Certifi ed Company®Check our website frequently for updates: www.freewatt.com www.ecrinternational.com

Pagina 66

72- INTRODUCTIONFigure 2-1 - freewatt PLUS System Components ( Zoned with Circulators)Figure 2 -2 freewatt PLUS Boilerfreewatt® PLUS System Componen

Pagina 67

8Table 2-1 System Rating and SizingUnitInput(MBH)HeatingCapacity(MBH)OverallEffi ciency(%)NominalPower(kWe)Weight(lbs)Honda MCHP Unit (0 - 3,300’)MCH

Pagina 68 - www.ecrinternational.com

9Figure 2-3 MCHP & Hydronic Hybrid Integration ModuleFigure 2-4b Hydronic Hybrid Integration Module2- INTRODUCTIONFigure 2-4a Hydronic Hybrid I

Commenti su questo manuale

Nessun commento