Smart-UPS
®
RT
Uninterruptible Power Supply
SURT 8000/10000 VA
200-240 VAC
Tower/Rack-Mount 6U
English
© 2012 APC by Schneider Electric. APC, the APC logo, Smart-UPS and PowerChute are owned by Schneider Electric
Industries S.A.S., American Power Conversion Corporation, or affiliated companies. All other trademarks are the property of
their respective owners.
990-2689G 09/2012
Vedere la pagina 0
1 2 3 4 5 6 ... 18 19

Sommario

Pagina 1 - Smart-UPS

Smart-UPS® RT Uninterruptible Power Supply SURT 8000/10000 VA 200-240 VAC Tower/Rack-Mount 6U English © 2012 APC by Schneider Electric.

Pagina 2

Feature Function Normal /Bypass Manually switch connected equipment to bypass mode, so that utility power is sent directly to connected equipment. B

Pagina 3 - INSTALLATION

USER CONFIGURABLE ITEMS NOTE: SETTINGS ARE MADE THROUGH SUPPLIED POWERCHUTE SOFTWARE, NETWORK MANAGEMENT CARD, OPTIONAL SMART SLOT ACCESSORY CARDS O

Pagina 4 - Hardwiring

NOTE: SETTINGS ARE MADE THROUGH SUPPLIED POWERCHUTE SOFTWARE, NETWORK MANAGEMENT CARD, OPTIONAL SMART SLOT ACCESSORY CARDS OR TERMINAL MODE. FUNCTION

Pagina 5 - XLI MODEL

EPO (Emergency Power Off) Option The output power can be disabled in an emergency by closing a switch connected to the EPO. Adhere to national and lo

Pagina 6

Terminal Mode to Configure UPS Parameters Terminal Mode is a menu driven interface that enables enhanced configuration of the UPS. Connect the serial

Pagina 7

MAINTENANCE, SERVICE, WARRANTY, AND TRANSPORTING Replacing the Battery Module(s) This UPS has easy to replace, hot-swappable battery modules. Replace

Pagina 8 - ASIC CONNECTORS

TROUBLESHOOTING Use the table below to solve minor installation and operation problems. Refer to the APC Web site, www.apc.com for assistance with com

Pagina 9 - OPERATION

15 PROBLEM AND POSSIBLE CAUSE SOLUTION BYPASS LED ILLUMINATES The bypass switch has been turned on manually or through an accessory. If bypass is

Pagina 10 - On Battery Operation

Service If the UPS requires service do not return it to the dealer. Follow these steps: 1. Review the problems discussed in the Troubleshooting secti

Pagina 11 - USER CONFIGURABLE ITEMS

17 RADIO FREQUENCY WARNINGS This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15

Pagina 13

Introduction The APC® by Schneider Electric Smart-UPS® RT is a high-performance, uninterruptible power supply (UPS) that provides protection for elec

Pagina 14

Hardwiring Wiring must be performed by a qualified electrician. 1. Install a utility circuit breaker in accordance with local electrical codes (see t

Pagina 15 - Transporting the UPS

7. XLI model only: For three-phase input, set the Input Phase Selector switch (see C) to ‘3’. For single-phase input, leave switch in default positi

Pagina 16 - TROUBLESHOOTING

Installing and Connecting the Batteries and Attaching the Front Bezel       4

Pagina 17

CONNECTING POWER AND EQUIPMENT TO THE UPS 1. Hardwire the UPS (see Hardwiring). 2. Connect equipment to the UPS (cables not included for XLT/XLJ/XL

Pagina 18 - Limited Warranty

BASIC CONNECTORS Serial Port Power management software and interface kits can be used with the UPS. Use only interface kits supplied or approved by

Pagina 19 - RADIO FREQUENCY WARNINGS

OPERATION FRONT DISPLAY PANEL Indicator Description Online The UPS is drawing utility power and performing double conversion to supply power